Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
American Mineralogist Email Content Delivery
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

American Mineralogist; January 2005; v. 90; no. 1; p. 132-142; DOI: 10.2138/am.2005.1552
© 2005 Mineralogical Society of America
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsuchiyama, A.
Right arrow Articles by Ikeda, S.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Quantitative evaluation of attenuation contrast of X-ray computed tomography images using monochromatized beams

Akira Tsuchiyama1,*, Kentaro Uesugi2, Tsukasa Nakano3 and Susumu Ikeda4

1 Department of Earth and Space Science, Osaka University, Toyonaka, 560-0043, Japan
2 SPring-8/Japan Synchrotron Radiation Research Institute, Mikazuki, Hyogo Prefecture, 679-5198 Japan
3 Geological Survey of Japan/National Institute of Advanced Industrial Science and Technology, Tsukuba, 305-8567 Japan
4 Department of Complexity Science and Engineering, Graduate School of Frontier Sciences, The University of Tokyo, Kashiwanoha 5-1-5, Kashiwa, Chiba 277-8561, Japan

Correspondence: * E-mail: akira{at}ess.sci.osaka-u-ac.jp

A quantitative relation between the linear attenuation coefficient (LAC) obtained by Synchrotron Radiation X-ray computed tomography (observed LAC) and the theoretically calculated LAC (theoretical LAC) of standard materials (minerals and metals) has been obtained for an X-ray microtomographic system at BL20B2 of SPring-8, Japan. This system, called SP-µCT, uses highly monochromatized and well-collimated X-ray beams produced by a synchrotron radiation source. Three-dimensional images were obtained for samples 0.4–4 mm in size at X-ray energies of 15–35 keV with a voxel size of 5.83 x 5.83 x 5.83 µm3. A histogram of the observed LAC for each sample was well-fitted by a Gaussian curve except for heavy metals whose X-ray transmittance was insufficient. The contrast resolution of CT images is best (within 5% of the LAC value) at LACs of about 10–30 cm–1. A garnet schist was imaged with SP-µCT to verify the observed–theoretical LAC relation for minerals contained in a rock sample. The result was consistent with the relation obtained for the standards. The CT and back-scattered electron images of the rock sample were compared. The present results put restrictions on discrimination of mineral phases and estimation of chemical compositions (e.g., Mg/Fe ratio) of certain minerals forming solid solutions based on CT values. The present quantitative relationship between observed and theoretical LACs enables us to obtain an absolute elemental concentration map by imaging just above and below the X-ray absorption edge energy of the element (subtraction method).







JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2008 by Mineralogical Society of America